Skip to main content

ISO 17089-1:2010

Withdrawn Date published:

Warning: Withdrawn Standard. This document has been replaced by:

Measurement of fluid flow in closed conduits - Ultrasonic meters for gas — Part 1: Meters for custody transfer and allocation measurement

ISO 17089-1:2010 specifies requirements and recommendations for ultrasonic gas flowmeters (USMs), which utilize the transit time of acoustic signals to measure the flow of single phase homogenous gases in closed conduits.

ISO 17089-1:2010 applies to transit time ultrasonic gas flowmeters used for custody transfer and allocation metering, such as full-bore, reduced-area, high-pressure, and low-pressure meters or any combination of these. There are no limits on the minimum or maximum sizes of the meter. ISO 17089-1:2010 can be applied to the measurement of almost any type of gas, such as air, natural gas, and ethane.

Included are flow measurement performance requirements for meters of two accuracy classes suitable for applications such as custody transfer and allocation measurement.

ISO 17089-1:2010 specifies construction, performance, calibration, and output characteristics of ultrasonic meters for gas flow measurement and deals with installation conditions.

Get this standard Prices exclude GST
PDF ( Single user document)
$118.26 NZD
HardCopy
$152.17 NZD
Networkable PDF
Price varies
Preview only close
Prev {{ page }}/ {{ numPages }} Next
Preview only close
Prev {{ page }}/ {{ numPages }} Next
Pages: 100

Keep me up-to-date

Sign up to receive updates when there are changes to this standard

Related Information

Similar Standards

  • BS 1042-2.2:1983

    Measurement of fluid flow in closed conduits. Velocity area methods, Method of measurement of velocity at one point of a conduit of circular cross section

  • BS 5857-1.1:1980

    Methods for measurement of fluid flow in closed conduits, using tracers. Measurement of water flow, General

  • BS 5857-1.2:1980

    Methods for measurement of fluid flow in closed conduits, using tracers. Measurement of water flow, Constant rate injection method using non-radioactive tracers

  • BS 5857-1.3:1980

    Methods for measurement of fluid flow in closed conduits, using tracers. Measurement of water flow, Constant rate injection method using radioactive tracers

Preview only close
Prev {{ page }}/ {{ numPages }} Next
Preview only close
Prev {{ page }}/ {{ numPages }} Next
Pages: 100

ISO 17089-1:2010

Get this standard Prices exclude GST
PDF ( Single user document)
$118.26 NZD
HardCopy
$152.17 NZD
Networkable PDF
Price varies

Request to add this standard to your subscription

ISO 17089-1:2010

Price varies
Online library subscription

Your organisation’s Account Administrator must approve a request to add a standard to your subscription.

You may add a comment to the administrator below.

Cancel