IEC 60079-6:2015

Current Date published:

Explosive atmospheres - Part 6: Equipment protection by liquid immersion "o"

IEC 60079-6:2015 specifies the requirements for the design, construction, testing and marking of Ex Equipment and Ex Components with type of protection liquid immersion "o" intended for use in explosive gas atmospheres. Ex Equipment and Ex Components of type of protection liquid immersion "o" are either:
- Level of Protection "ob" (EPL "Mb" or "Gb") or
- Level of Protection "oc" (EPL "Gc"). For Level of Protection "ob", this standard applies where the rated voltage does not exceed 11 kV r.m.s. a.c. or d.c. For Level of Protection "oc", this standard applies where the rated voltage does not exceed 15 kV r.m.s. a.c. or d.c. This standard supplements and modifies the general requirements of IEC 60079-0. Where a requirement of this standard conflicts with a requirement of IEC 60079-0, the requirement of this standard takes precedence. This fourth edition cancels and replaces the third edition, published in 2007. This edition constitutes a technical revision. The significant changes with respect to the previous edition are:
- Edition 4 represents a major technical revision of the requirements for oil immersion "o" and should be considered as introducing all new requirements. The normal "Table of Significant Changes" has not been included for this reason. In particular:
- The requirements for oil immersion "o" have been redefined into liquid immersion, levels of protection "ob" and "oc" as recommended by the responses to 31/715/DC;
- The ability to protect sparking contacts has been added to both "ob" and "oc". Additional requirements have been introduced for the protective liquid. Keywords: Ex Equipment and Ex Components with type of protection liquid immersion "o"

Get this standard Prices exclude GST
PDF ( Single user document)
$260.00 NZD
HardCopy
$251.30 NZD
Networkable PDF
Price varies
Preview only close
Prev {{ page }}/ {{ numPages }} Next
Preview only close
Prev {{ page }}/ {{ numPages }} Next

Keep me up-to-date

Sign up to receive updates when there are changes to this standard

Related Information

Similar Standards

  • AS/NZS 1299:2009

    Electrical equipment for mines and quarries - Explosion-protected three-phase restrained plugs and receptacles for working voltages up to and including 3.3 kV

  • AS/NZS 1299:2009 A1


    Electrical equipment for mines and quarries - Explosion-protected three-phase restrained plugs and receptacles for working voltages up to and including 3.3 kV: Amendment 1:2012

  • AS/NZS 1300:2009

    Electrical equipment for mines and quarries - Bolted explosion-protected three-phase cable coupling devices

  • AS/NZS 1300:2009 A1


    Electrical equipment for mines and quarries - Bolted explosion-protected three-phase cable coupling devices: Amendment 1:2012

Preview only close
Prev {{ page }}/ {{ numPages }} Next
Preview only close
Prev {{ page }}/ {{ numPages }} Next

IEC 60079-6:2015

Get this standard Prices exclude GST
PDF ( Single user document)
$260.00 NZD
HardCopy
$251.30 NZD
Networkable PDF
Price varies

Request to add this standard to your subscription

IEC 60079-6:2015

Price varies
Online library subscription

Your organisation’s Account Administrator must approve a request to add a standard to your subscription.

You may add a comment to the administrator below.

Cancel