ISO 7194:2008

Current Date published:

Measurement of fluid flow in closed conduits — Velocity-area methods of flow measurement in swirling or asymmetric flow conditions in circular ducts by means of current-meters or Pitot static tubes

ISO 7194:2008 specifies velocity-area methods for measuring flow in swirling or asymmetric flow conditions in circular ducts by means of current-meters of Pitot static tubes.

ISO 7194:2008 specifies the measurements required, the precautions to be taken, the corrections to apply, and describes the additional uncertainties which are introduced when a measurement in asymmetric or swirling flow has to be made.

Only flows with a negligible radial component are considered, however. Furthermore, it is not possible to make a measurement in accordance with ISO 7194:2008 if, at any point in the measuring cross-section, the local velocity makes an angle of greater than 40° with the axis of the duct, or where the index of asymmetry Y (defined within ISO 7194:2008) is greater than 0,15.

ISO 7194:2008 deals only with instruments for measuring local velocity as defined in ISO 3354 and ISO 3966. If Pitot static tubes are used, ISO 7194:2008 applies only to flows where the Mach number corresponding to local velocities does not exceed 0,25.

Get this standard Prices exclude GST
PDF ( Single user document)
$281.74 NZD
HardCopy
$319.13 NZD
Networkable PDF
Price varies
Preview only close
Prev {{ page }}/ {{ numPages }} Next
Preview only close
Prev {{ page }}/ {{ numPages }} Next
Pages: 27

Previous versions

Keep me up-to-date

Register to receive notifications when updates are made to this standard.

Related Information

Similar Standards

  • BS 1042-2.2:1983

    Measurement of fluid flow in closed conduits. Velocity area methods, Method of measurement of velocity at one point of a conduit of circular cross section

  • BS 5857-1.1:1980

    Methods for measurement of fluid flow in closed conduits, using tracers. Measurement of water flow, General

  • BS 5857-1.2:1980

    Methods for measurement of fluid flow in closed conduits, using tracers. Measurement of water flow, Constant rate injection method using non-radioactive tracers

  • BS 5857-1.3:1980

    Methods for measurement of fluid flow in closed conduits, using tracers. Measurement of water flow, Constant rate injection method using radioactive tracers

Preview only close
Prev {{ page }}/ {{ numPages }} Next
Preview only close
Prev {{ page }}/ {{ numPages }} Next
Pages: 27

Previous versions

ISO 7194:2008

Get this standard Prices exclude GST
PDF ( Single user document)
$281.74 NZD
HardCopy
$319.13 NZD
Networkable PDF
Price varies

Request to add this standard to your subscription

ISO 7194:2008

Price varies
Online library subscription

Click "Send request for subscription" to ask your Account Administrator to add this standard to your subscripiton.

Cancel